Sri Lanka Septic Tank Size Calculator
Size a domestic septic tank from the number of occupants, the type of wastewater and how often you desludge. Get the required volume in litres and m³ plus a suggested length × width to hand to your mason — using the SLS 745 / IS 2470 method, no signup, sources cited.
How it works
A septic tank has to do two jobs at once: hold incoming sewage long enough for solids to settle, and store the sludge that builds up until the next desludging. Its effective liquid volume is therefore the sum of a retention component and a sludge-storage component, per the SLS 745 code and the IS 2470 (Part 1) design method it is based on.
- Retention (detention) volume
A = P × q × Tr— persons P times per-capita wastewater flow q (litres/person/day) held for a detention time Tr in days. SLS 745 / IS 2470 set a minimum 24-hour (Tr = 1 day) detention. - Sludge + scum storage volume
B = P × G × N— persons times the sludge accumulation rate G (litres/person/year, ~25 per the WHO on-site sanitation guide) over the desludging interval N in years. - Required liquid volume
V = A + B, which is algebraically the IS 2470 combined formV = P × (q·Tr + G·N). The calculator computes both and confirms they agree to the litre. - Minimum-capacity floor. If the computed V falls below 1,000 litres, the IS 2470 minimum domestic liquid capacity of 1,000 litres (1.0 m³) governs instead — the tool flags when this happens.
- Dimensions. At a chosen liquid depth D in metres, the plan area is
(V/1000) ÷ D. For a length:width ratio r (IS 2470 permits 2:1 to 4:1), widthW = √(area ÷ r)and lengthL = r × W. A 300 mm freeboard is added on top of the liquid depth to give the total tank depth.
Every input — flow, detention, sludge rate, depth and ratio — is shown in the “advanced” panel and reflected in the breakdown table, so no constant is hidden. The defaults are the SLS 745 / IS 2470 / WHO domestic figures; change them only where your local authority specifies otherwise. This tool sizes the septic tank alone, not the downstream soakage pit, which depends on a soil percolation test.
Worked examples
Frequently asked questions
Sources & references
- SLS 745 — Code of Practice for the Design and Construction of Septic Tanks (Sri Lanka Standards Institution)
- IS 2470 (Part 1):1985 — Installation of Septic Tanks, Design Criteria (full text)
- National Water Supply & Drainage Board (NWSDB) — on-site sanitation guidance
- WHO — A Guide to the Development of On-site Sanitation (Franceys, Pickford & Reed)
The design method, the 1,000 L minimum liquid capacity, the 300 mm freeboard and the per-capita constants were cross-checked against these sources on 2026-07-11. Local-authority requirements can differ; always confirm before building.
Related tools
Comments & feedback
Spotted a bug or want an improvement? Tell us — our team reviews every comment, and good ideas get built. Comments are public and anonymous.
Found a bug, edge case, or want to suggest an improvement?
Email me at [email protected] — most fixes ship within 24 hours.